Showing posts with label remote. Show all posts
Showing posts with label remote. Show all posts

Wednesday, October 29, 2014

GSM Remote Control Software

PC configuration software for all remote controls described in the last four issues. This application is used to set all parameters via PC, instead of using the boring and expensive SMS configuration system.
In the articles devoted to the remote GSM modules, we have repeatedly mentioned that the programming of the numbers in the list of those qualified to command the devices and the configuration of all operating parameters could be done avoiding the long and expensive procedure through SMS; in fact we made reference to an application software that could take advantage of the USB interface to connect with our modules and check the current settings or to add new configurations. Well, now is time to talk about this program, created to facilitate the task of those who must install our TDGs. This program is really useful for the gate opener where a lot of time could be spent entering from a mobile phone, via SMS, the many numbers a phone can contain and that would cost quite a lot (unless you have a special free SMS formula with your service provider).
The software runs on Windows and needs relatively limited resources, in fact, the system requirements basically are:
- 30 MB of free space on your Hard Disk;
- a free USB port;
- XP/2000/Vista/7 OS Microsoft Windows – 32-bit or 64 bit.
This software allows you to set the settings for Remote Control, just connect the device via USB and the computer will immediately recognize the device since among other functions, our program automatically recognizes the remote that is connected. In practice, according to the connected device the program adapts its user interface, showing in the main dialog box only the tabs that relate to its configuration, excluding the rest.
Software
Initial screen of the software
Let’s now we see how to use the program and what are the functions therein.
Boxes Com Port  and Baud Rate summarize the information about the virtual open COM for the USB connection.
First of all, in the Information tab we find a summary of all the characteristics of the remote control during the configuration phase, i.e. model (TDG133. .. TDG140), firmware version and IMEI of the cell module installed.
Information
The bottom section contains log information about the events registered by  the remote.
In the menu bar there are two commands:
Exit which allows you to leave the program and Database  which opens the window Phonebook, this window displays the stored phone numbers; in this window the buttons Clear List and  Update List  allow you to remove the directory or to update it. In the latter case, the program sends the new phonebook to the remote. Clicking on the question mark, instead, you get information about the program, i.e. release and more.
It should be noted that in the lower section of the main window, there is the indication “pending call from Master Number” in case you connect a remote control that has not stored at least one number, or in which the Easy Setup has not been performed.
In the same section, by clicking on Enable Extended LOG you access the dialog box shown on the left, in Figure 4, which contains all data received on the “COM” port of the computer you are using.
The Master Numbers section summarizes the numbers in the list (8 maximum) authorized to carry out the configuration and issue commands via SMS.
Phone
Let’s see the main program window when you connect a remote DTMF (TDG140): it shows the storage of a number of those qualified to command, note that you can define (using the Position box) the position where to store the number as well as the name of the person who owns the phone you are storing.
The Phone Numbers  tab can be seen connecting any remote control version to the computer. Let’s now see the main window, specific for the TDG133 gate opener and the TDG134: note, in the right section, the tab Gate Opener Numbers, next to tab Master Numbers. By clicking on that tab, you access the window that summarizes the list of numbers related to the gate open control.
Master
The main window of the program, in addition, offers the tab Telephone Numbers, which is different from the one seen before: in fact here there are two sections that are used to store and display both the master numbers (Master Numbers) as well as the names of the phones that can simply operate the remote control relay (Gate Open Numbers). Only for master numbers there is the possibility to specify the position where to save them.
Gate
Extended

Well, let’s now take a look at the Notices window that we can find in the remote control with two inputs, in the DTMF remote control and in the GSM thermostat.
There, you can specify, for each phone number included in the list of master numbers, that in case of failure it has to receive the alert via SMS, with a simple phone call, or by means of both methods. The selection is made by putting a tick in the boxes, on the understanding that it is not mandatory for the numbers to receive the notifications: the remote control also works without activating the function.
SMS
For the GSM remote control 2 IN – 2 OUT, and the DTMF remote there is, in the main window, a tab used to set the alarm logic and the timing for the detection of the input alarms. Specifically, the tab allows to check (by querying the remote control) or to change the alarm conditions recognized at the inputs, namely the activation logic (i.e. if the input must be considered in alarm when power is supplied or in absence of power or just when there is a change in the status) the inhibition time between a level determining an alarm and the next one, as well as the observation period, that is the time range for which the alarm condition must persist in order to be considered as such.
Input
When checking the option box Request Set Times  and by clicking on Run on the Timing  section, you can request the state of the intervals set for the recognition of the input alarms, the program responds with the notice box shown here.
Information 
Continue Reading at 
http://www.open-electronics.org/gsm-remote-control-software/4/ 
Read More..

Tuesday, September 23, 2014

DTMF Remote Control RC Radio Circuit

Here is a remote control (RC) radio unit circuit which makes use of the radio frequency signals to control various electrical appliances. This remote control unit has 4 channels which can be easily extended to 12. This RC circuit differs from similar circuits in view of its simplicity and a totally different concept of generating the control signals.

Here we make use of DTMF (dual-tone multi frequency) signals (used in telephones to dial the digits) as the control codes. The DTMF tones are used for frequency modulation of the carrier. At the receiver unit, these frequency modulated signals are intercepted to obtain DTMF tones at the speaker terminals.

Remote Control Radio Circuit Schematic

The remote control transmitter consists of DTMF generator and an FM transmitter circuit. For generating the DTMF frequencies, a dedicated IC UM91214B (which is used as a dialler IC in telephone instruments) is used here. This IC requires 3 volts for its operation. This is provided by a simple zener diode voltage regulator which converts 9 volts into 3 volts for use by this IC.

Rest of the pins of this IC may be left as they are. The output of IC1 is given to the input of this transmitter circuit which effectively frequency modulates the carrier and transmits it in the air. The carrier frequency is determined by coil L1 and trimmer capacitor VC1 (which may be adjusted for around 100 MHz operation). An antenna of 10 to 15 cms (4 to 6 inches) length will be sufficient to provide adequate range.

The antenna is also necessary because the transmitter unit has to be housed in a metallic cabinet to protect the frequency drift caused due to stray EM fields. Four key switches (DPST push-to-on spring loaded) are required to transmit the desired DTMF tones. The switches when pressed generate the specific tone pairs as well as provide power to the transmitter circuit simultaneously. This way when the transmitter unit is not in use it consumes no power at all and the battery lasts much longer.

The receiver unit consists of an FM receiver (these days simple and inexpensive FM kits are readily available in the market which work exceptionally well), a DTMF-to-BCD converter and a flip-flop toggling latch section. The frequency modulated DTMF signals are received by the FM receiver and the output (DTMF tones) are fed to the dedicated IC KT3170 which is a DTMF-to-BCD converter.

Read More..

Saturday, September 13, 2014

Remote Field Strength Meter Wiring diagram Schematic

Remote Field Strength Meter Circuit Diagram. This field strength meter consists of a tuned crystal detector producing a dc output voltage from a transmitted signal. The dc voltage is used to shift the frequency of a transmitter of 100-mW power operating at 1650 kHz. The frequency shift is proportional to the received field strength. This unit has a range of several hundred feet and is operated under FCC part 15 rules (100-mW max power into a 2-m-iong antenna between 510 and 1705 kHz).

Remote Field Strength Meter Circuit Diagram

Remote

Read More..

Friday, September 5, 2014

Radio Remote Control using DTMF

Here is a schema of a remote control unit which makes use of the radio frequency signals to control various electrical appliances. This remote control unit has 4 channels which can be easily extended to 12.








This schema differs from similar diagram in view of its simplicity and a totally different concept of generating the control signals. Usually remote control diagram make use of infrared light to transmit control signals. Their use is thus limited to a very confined area and line-of-sight. However, this schema makes use of radio frequency to transmit the control signals and hence it can be used for control from almost anywhere in the house. Here we make use of DTMF (dual-tone multi frequency) signals (used in telephones to dial the digits) as the control codes. The DTMF tones are used for frequency modulation of the carrier. At the receiver unit, these frequency modulated signals are intercepted to obtain DTMF tones at the speaker terminals. This DTMF signal is connected to a DTMF-to-BCD converter whose BCD output is used to switch-on and switch-off various electrical applicances (4 in this case). The remote control transmitter consists of DTMF generator and an FM transmitter schema. For generating the DTMF frequencies, a dedicated IC UM91214B (which is used as a dialler IC in telephone instruments) is used here. This IC requires 3 volts for its operation. This is provided by a simple zener diode voltage regulator which converts 9 volts into 3 volts for use by this IC. For its time base, it requires a quartz crystal of 3.58 MHz which is easily available from electronic component shops. Pins 1 and 2 are used as chip select and DTMF mode select pins respectively. When the row and column pins (12 and 15) are shorted to each other, DTMF tones corresponding to digit 1 are output from its pin 7. Similarly, pins 13, 16 and 17 are additionally required to dial digits 2, 4 and 8. Rest of the pins of this IC may be left as they are. The output of IC1 is given to the input of this transmitter schema which effectively frequency modulates the carrier and transmits it in the air. The carrier frequency is determined by coil L1 and trimmer capacitor VC1 (which may be adjusted for around 100MHz operation). An antenna of 10 to 15 cms (4 to 6 inches) length will be sufficient to provide adequate range. The antenna is also necessary because the transmitter unit has to be housed in a metallic cabinet to protect the frequency drift caused due to stray EM fields. Four key switches (DPST push-to-on spring loaded) are required to transmit the desired DTMF tones. The switches when pressed generate the specific tone pairs as well as provide power to the transmitter schema simultaneously. This way when the transmitter unit is not in use it consumes no power at all and the battery lasts much longer. The receiver unit consists of an FM receiver (these days simple and inexpensive FM kits are readily available in the market which work exceptionally well), a DTMF-to-BCD converter and a flip-flop toggling latch section. The frequency modulated DTMF signals are received by the FM receiver and the output (DTMF tones) are fed to the dedicated IC KT3170 which is a DTMF-to-BCD converter. This IC when fed with the DTMF tones gives corresponding BCD output; for example, when digit 1 is pressed, the output is 0001 and when digit 4 is pressed the output is 0100. This IC also requires a 3.58MHz crystal for its operation. The tone input is connected to its pin 2 and the BCD outputs are taken from pins 11 to 14 respectively. These outputs are fed to 4 individual ‘D’ flip-flop latches which have been converted into toggle flip-flops built around two CD4013B ICs. Whenever a digit is pressed, the receiver decodes it and gives a clock pulse which is used to toggle the corresponding flip-flop to the alternate state. The flip-flop output is used to drive a relay which in turn can latch or unlatch any electrical appliance. We can upgrade the schema to control as many as 12 channels since IC UM91214B can generates 12 DTMF tones. For this purpose some modification has to be done in receiver unit and also in between IC2 and toggle flip-flop section in the receiver. A 4-to-16 lines demultiplexer (IC 74154) has to be used and the number of toggle flip-flops have also to be increased to 12 from the existing 4

Read More..